daq assistant multiple analog inputs onto different graphs

$
0
0

I am having trouble viewing data coming out of a single daq assistant with mutiple analog inputs. I am using 4 different waveform graphs to show 4 different analog voltages coming in. Im using a signal split function from the single daq assisant to the 4 graphs but it seems all the graphs are showing the same values when the voltages change. The daq im using is the NI USB-6210. This is for a graduate electrical engineering project, so I'm still a beginner to labview. I have also added a "from DDT" function for each of the 4 graphs right after the signal split but that also didnt work. Also when I view the signals from the properties window of the daq assistant using the 'run' button, all the signals seem to move together but a few mV off. Im not sure if my daq is setup wrong or my block diagram.

 

The purpose of this project is to view 5 different voltages coming from 5v "wall" source, a small turbine generator, a battery, and a solar panel. The last output is a light sensor but all that needs to do is show when the light sensor is above 1.5V (this is "ON" for the light sensor)

I also have 4 digital outputs for switches but that part of the labview works fine!

 